01Overview

Your CNG cylinder holds gas at 200 bar — about ninety times the pressure in a car tyre. Every three years it has to prove it can still take it. Proving that is what we do.

  • Auto-rickshawsShare & passenger autos
  • Cars & taxisFactory-fitted & retrofitted
  • BikesCNG two-wheelers
  • Vans, buses & fleetsSingle & multi-cylinder kits
  • CNG stationsCascade cylinders
  • IndustryOxygen, nitrogen, argon, CO2, hydrogen

02ServicesWhat we do

Eight cylinder types. One standard of care.

End to end, every time. Identification, inspection, testing, drying, valve refitting, re-test marking and certification.

03Equipment & resourcesWhat we have

The hardware behind every certificate.

E—01

Test rig

Hydrostatic test bench

Fills the cylinder with water, takes it to test pressure and measures its volumetric expansion.

Pressure
Test at 350 kg/cm²
Used for
Hydrostatic test · Volumetric expansion
E—02

Pump

High-pressure test pump

Raises the pressure steadily, holds it at the test point and releases it under control.

Function
Controlled rise, hold and release
Used for
Hydrostatic test
E—03

Ultrasonic

Ultrasonic flaw detector

Finds cracks and flaws inside the steel that the eye cannot see.

Checks
Body and cylindrical parts
Used for
Ultrasonic flaw detection
E—04

Ultrasonic

Ultrasonic thickness gauge

Measures the wall thickness of the cylinder without cutting or marking it.

Checks
Wall thickness
Used for
Thickness measurement
E—05

Weighing

Tare-weight scale

Checks the empty weight of the cylinder as part of the inspection.

Checks
Tare weight
Used for
Inspection
E—06

Safety

Degassing station

Releases the remaining gas safely and brings the cylinder to zero before any work begins.

Function
Controlled release of residual gas
Used for
Degassing
E—07

Cleaning

Cleaning & drying unit

Cleans the cylinder outside and inside before inspection, and dries it fully after the water test.

Function
External and internal cleaning · Drying
Used for
Every test
E—08

Inspection

Visual & neck inspection

Lights up the inside of the cylinder for the visual inspection and checks the condition of the neck.

Checks
Outer wall · Inner wall · Neck
Used for
Visual inspection
E—09

Tools

Valve refitting bench

Takes the valve off before the test and refits it correctly once the cylinder is dry.

Function
Valve removal and refitting
Used for
Every test
E—10

Marking

Re-test marking & records

Marks each passed cylinder with its re-test details and produces its test report and certificate.

Output
Re-test marking · Report · Certificate
Used for
Certification

Our locations

Find the plant nearest you.

Across Tamil Nadu.

Find a plant

04LocationsWhere we operate

Our locations. All of Tamil Nadu.

TAMIL NADU

Tamil Nadu · our locations

05Our journeyHow we work

Twelve checks. Zero shortcuts.

01

Identify

Every cylinder is identified and its identity recorded before anything else happens: serial number, make, capacity and the date of its last test.

Serial number, make and last test date are recorded first.

  • 1 · Identification
  • 2 · Identity recorded
02

Degas

The remaining gas is released safely until the cylinder is at zero pressure. Only then does the valve come off.

The remaining gas is released safely, then the valve comes off.

  • 3 · Degassing
03

Clean

The cylinder is cleaned outside and inside, so that nothing can hide a defect from the inspection that follows.

Cleaned outside and inside, so no defect can hide.

  • 4 · External & internal cleaning
04

Inspect

A visual inspection inside and out, then ultrasonic flaw detection, a tare-weight check, ultrasonic thickness measurement and a close look at the neck.

Visual and ultrasonic checks, tare weight, wall thickness and neck.

  • 5 · Visual inspection
  • 6 · Ultrasonic flaw detection
  • 7 · Tare weight
  • 8 · Thickness measurement
  • 9 · Cylindrical parts
  • 10 · Neck
05

Hydro test

The cylinder is filled with water and taken to 350 kg/cm². We measure how much it expands under pressure, and whether it recovers.

Filled with water and taken to 350 kg/cm². Expansion is measured.

  • 11 · Hydrostatic test
  • 12 · Volumetric expansion
06

Dry & refit

The water is emptied out, the cylinder is dried completely, and the valve is refitted.

Water out, cylinder dried completely, valve refitted.

  • Drying
  • Valve refitting
07

Mark & certify

A cylinder that passes gets its re-test marking, and you get its test report and certificate.

The cylinder gets its re-test marking. You get the report and certificate.

  • Re-test marking
  • Test report
  • Certificate

06Trust & credibilityWhy choose us

Why customers trust Diya.

Diya CNG Hydro Testing Center provides hydrostatic testing, inspection and certification services for CNG and industrial high-pressure cylinders.

Our team works on CNG fitment as well as testing, so we understand the practical requirements of CNG vehicles, fleets, fuel stations and cylinder users.

With testing facilities in several cities, we support customers across Tamil Nadu with dependable testing, inspection and certification services.

Your one stop CNG partnerwww.diyahydrotesting.com

Vision

CNG that every driver, passenger and family can trust without a second thought.

Mission

Safe, compliant and reliable cylinder testing: done properly, documented fully, and explained plainly.

Philosophy

Safety first. A certificate should mean exactly what it says.

Companies we have served

        Our strengths

        • Eight cylinder types

          CNG, cascades, industrial gas, oxygen, nitrogen, hydrogen, argon and CO2: tested under one roof.

        • Practical knowledge

          We understand what CNG vehicles, fleets, fuel stations and cylinder users actually need.

        • Safety-first testing

          Hydrostatic testing carried out with safety-first practices at every stage.

        • Ultrasonic inspection

          Ultrasonic flaw detection and thickness measurement, not only a visual check.

        • Detailed reports

          Every cylinder leaves with a detailed test report and its certification.

        • Our locations

          Several cities: accessible testing support across Tamil Nadu.

        Certifications & compliance

          Who we test for

          • CNG vehicle owners
          • Fleet operators
          • CNG fuel stations
          • Manufacturing units
          • Welding & fabrication
          • Laboratories
          • Beverage plants
          • Fire-safety services

          What customers say

          07Support & contactConnect with us

          Is your cylinder due?
          Let's test it.

          Call+91 00000 00000 WhatsAppMessage us

          Send an enquiry

          Tell us about your cylinder. Your message opens in WhatsApp, ready to send.

          SupportFrequently asked

          Questions customers ask us.

          How often does a CNG cylinder need testing?

          Every three years, counted from the last test date marked on the cylinder. That is the interval the Gas Cylinders Rules, 2016 set for CNG cylinders. Get it tested sooner if the vehicle has been in an accident or a fire, or if the cylinder shows damage.

          Which cylinders do you test?

          CNG vehicle cylinders, CNG cascade cylinders, and industrial gas cylinders: oxygen, nitrogen, hydrogen, argon and CO2.

          Where are your plants?

          Across Tamil Nadu. Customers from across the state use the plant nearest to them: see Locations for each address.

          What does the test involve?

          Twelve stages: identification, recording the identity, degassing, cleaning, visual inspection, ultrasonic flaw detection, a tare-weight check, ultrasonic thickness measurement, flaw detection of the cylindrical parts, neck inspection, the hydrostatic test and the volumetric expansion measurement. The cylinder is then dried, the valve is refitted, and the cylinder is marked and certified.

          What happens if my cylinder fails?

          A cylinder that fails cannot go back into service. We will show you why it failed and explain your options for a replacement.

          How long does the test take?

          It depends on the type and number of cylinders. Call or message us with the details and we will give you a time before you come in.

          Quick enquiry

          Book a cylinder test

          A few details and we will call you back — or reach us right now.